Current Detection Module Digital Display Sensor Protective Board Detector Switch DC 7‑30V

24,26 €
la livraison GRATUITE

Current Detection Module Digital Display Sensor Protective Board Detector Switch DC 7‑30V

  • Marque: Unbranded
Verkocht door:

Current Detection Module Digital Display Sensor Protective Board Detector Switch DC 7‑30V

  • Marque: Unbranded
Prix de vente conseillé : 53,38 €
Prix : 24,26 €
Vous économisez : 29,12 € (54%)
Verkocht door:
24,26 €
la livraison GRATUITE

En stock

Nous acceptons les modes de paiement suivants

Description

1、Current Sensor Module: Can easily detect the DC current and control the on and off of relay according to the set limit current. 2、Wide Detection Range: The voltage detection range is 7‑30V, and the current detection range is 0‑30A, meeting various needs. 3、Accurate Measurement: With a high measurement accuracy up to 0.1A, the sensor module has error calibration function as well. 4、Circuit Protection: Used to limit the current in the circuit and protect electrical equipment from damage caused by the current. 5、Convenient Operation: The digital display can be turned off for a long time to reduce power consumption, useful and convenient. Item Type: Current Detection Module Product Model: YYI-4 Voltage Detection Range: DC7-30V Current Detection Range: 0~30A Detection Accuracy: 0.1A (100mA). Standby Current: About 20mA. Relay Output: Can control the on and off of DC lines within 30A. Function: Detect whether the current is too large or too small, control the relay switch to control the line on and off, or give a signal. How to Use: No. 1 Operation Instructions: 1. P-11: When the measured current is greater than I1, the relay is closed; when the measured current is less than I1 again, the relay is disconnected; 2. P-12: When the measured current is greater than I1, the relay is closed; it always stays closed until the circuit board is powered off; 3. P-21: When the measured current is greater than I2, the relay is closed; when the measured current is less than I1, the relay is disconnected; 4. P-22: When the measured current is greater than I2, the relay is closed; it always stays closed until the circuit board is powered off; 5. P-31: When the measured current is less than I1, the relay is closed; when the current is greater than I2, the relay is disconnected; 6. P-32: When the measured current is less than I1, the relay is closed; it always stays closed until the circuit board is powered off; 7. P-41: When the measured current is between I1 and I2, the relay is closed, otherwise the relay is disconnected; 8. P-42: When the measured current is between I1 and I2, the relay is closed; it always stays closed until the circuit board is powered off; 9. P-51: When the measured current is less than I1 or greater than I2, the relay is closed, otherwise the relay is disconnected; 10.P-52: When the measured current is less than I1 or greater than I2, the relay will be closed; it will always be closed until the circuit board is powered off. No. 2 Setting Instructions: 1. Power on to display the measured current(if the measured current terminal is suspended, the number of digital display is normal); 2. The first time K1 is pressed, it takes more than 1 second to effective prevent false triggering. The screen displays: P 11: K2 adjustment mode, K3 adjustment function 3. Press K1 for the second time, the screen flashes 0.05 means that the value of the threshold I1 is 0.05A; K2 sets I1 plus, K3 sets I1 minus; 4. Press K1 for the third time, the screen flashes 0.10 means the value of the threshold I2 is 0.1A; K2 sets I2 plus, K3 sets I2 minus 5. Press K1 for the fourth time, the screen displays the measured current; it means it enters the standby state; 6. In standby mode, long press K2 or K3 to fine tune the measured current error. 1 x Current Detection Module
  • Identifiant Fruugo: 388423454-833297711
  • EAN: 680141656139

Informations sur la sécurité des produits

Veuillez consulter les informations de sécurité du produit spécifiques à ce produit décrites ci-dessous.

Les informations suivantes sont fournies par le détaillant tiers indépendant vendant ce produit.

Étiquettes de sécurité des produits

CE Mark
Avertissements de sécurité:
  • Not suitable for children under 36 months
  • Choking Hazard
  • Adult supervision recommended

Livraison & retours

Expédition dans un délai de 2 jours

  • STANDARD: GRATUIT - Livraison entre ven. 17 octobre 2025–lun. 27 octobre 2025 - GRATUIT

Expédition de Chine.

Nous mettons tout en œuvre pour que les produits que vous commandez vous soient livrés dans leur intégralité et selon vos indications. Néanmoins, si vous recevez une commande incomplète, des articles différents de ceux commandés ou si, pour toute autre raison, la commande ne vous satisfait pas, vous pouvez retourner la commande ou tout produit inclus dans celle-ci et recevoir un remboursement complet des articles. Voir l'intégralité de la politique de retour

Détails de conformité du produit

Veuillez consulter les informations de conformité spécifiques à ce produit décrites ci-dessous.

Les informations suivantes sont fournies par le détaillant tiers indépendant vendant ce produit.

Fabricant:
Les informations suivantes indiquent les coordonnées du fabricant du produit concerné vendu sur Fruugo.

  • Jinan Haoteseer Cross Border E-commerce Co.. Ltd.
  • Jinan Haoteseer Cross Border E-commerce Co.. Ltd.
  • No.9-43, East Tower, Shounuo City of Light
  • Huaiyin District, Jinan
  • China
  • Jinan
  • CN
  • 250000
  • jnamei03@163.com
  • 13380966881

Personne responsable dans l'UE:
Les informations suivantes indiquent les coordonnées de la personne responsable dans l'UE. La personne responsable est l'opérateur économique désigné basé dans l'UE qui est responsable des obligations de conformité relatives au produit concerné vendu dans l'Union européenne.

  • WongBo
  • NG HOT SARL
  • 99 bis avenue du Général Leclerc
  • 99 bis avenue du Général Leclerc
  • France
  • Paris
  • FR
  • 75014
  • ngnghot@outlook.com
  • 33695000695
  • https://www.captaincontrat.com/creer-son-entreprise/sarl/capital-social-de-sarl-montant-minimum-constitution-modification...tout-savoir