TTL Power Monitoring Communication Module for AC Voltage, Current, Power Frequency with CT (CT Coil 100A)

21,95 €
la livraison GRATUITE

TTL Power Monitoring Communication Module for AC Voltage, Current, Power Frequency with CT (CT Coil 100A)

  • Marque: Unbranded
Verkocht door:

TTL Power Monitoring Communication Module for AC Voltage, Current, Power Frequency with CT (CT Coil 100A)

  • Marque: Unbranded
Prix de vente conseillé : 28,95 €
Prix : 21,95 €
Vous économisez : 7,00 € (24%)
Verkocht door:
21,95 €
la livraison GRATUITE

En stock

Nous acceptons les modes de paiement suivants

Description

Feature: 1. This AC parameter communication module is mainly used to measure AC voltage, current, active power, frequency, power factor and active energy. 2. The module has no display function and the data is read through the TTL interface. 3. Support for Modbus-RTU standard protocol, including host computer software. 4. Comes with TTL to USB data cable and external CT. 5. The module works for Windows operating systems. Specification: Item Type: Communication Module Measurement Range: AC 80-260V Resolution: 0.1 V Accuracy:0.5% 2. Current: Measurement Range:0-100A Resolution: 0.001 A Accuracy: 0.5% 3. Active Power Measurement Range:0-2.3 KW Min. Measuring Power: 0.4W Resolution: 0.1W 4. Power Factor Measurement Range: 0.00-1.00 Resolution: 0.01 Accuracy:1% 5. Frequency Range:45 Hz-65 Hz Resolution: 0.1 Hz Accuracy: 0.5% 6. Active Electrical Energy Metering Range:0-9999.99 kWh Resolution: 1Wh Accuracy: 0.5% Communication Protocol: 1. Physical layer protocol: Physical layer adopts UART to TTL communication interface Baud rate:9600,8 bit data bit,1 bit stop bit, no check 2. Application layer protocol The application layer supports for Modbus-RTU protocol for communication and currently only supports function codes such as 0x03 (read-hold register), 0x04 (read-input register), 0x06 (write single register), 0x41 (calibration), 0x42 (power zero). The 0x41 function code is limited to internal use (the address can only be 0xF8), used for factory calibration and back-to-factory maintenance, add a password of 16 bits after the function code, the password default is 0x3721. The address range of the slave computer is 0x01 ~ 0xF7, and the address 0x00 is used as the broadcast address. The slave computer does not need to reply to the host, and the address 0xF8 is used as the general address. The address can only be used in a single-slave environment and can be used for calibration and other operations. 3. Read the results of the measurement The command format for the host to read the result of the measurement is (8 bytes in total): Slave computer address + 0x04 + register address high byte + register address low byte + register number high byte + register number low byte + CRC check high byte + CRC check low byte. Reply of slave computer to the following command format is divided into two types: Correct reply: Slave computer address + 0x04 + bytes + registers 1 data high byte + registers 1 data low byte +...+ CRC check high byte + CRC check low byte. Wrong reply: Slave computer address + 0x84 + exception code + CRC check high byte + CRC check low byte. The exception code is read as follows (the same below): 0x01, illegal function; 0x02, illegal address; 0x03, illegal data; 0x04, slave error. The register layout of the measured results is shown in the following table: v\:* {behavior:url(#default#VML);} o\:* {behavior:url(#default#VML);} x\:* {behavior:url(#default#VML);} .shape {behavior:url(#default#VML);} Register address Description Resolution 0x000 Voltage value measurement 1LSB corresponds to 0.1V 0x001 Current Measurement Value Low 16 Bits 1LSB corresponds to 0.01A 0x0002 Current Measurement Value High 16 Bits 0x0003 Power Measurement Value Low 16 Bits 1LSB corresponds to 0.1W 0x0004 Power Measurement Value High 16 Bits 0x0005 Energy Measurement Value Low 16 Bits 1LSB corresponds to 1Wh 0x0006 Energy Measurement Value High 16 Bits 0x0007 Frequency Measurement Value 1LSB corresponds to 0.1Hz 0x0008 Power Factor Measurement Value 1LSB corresponds to 0.01 0x0009 Alarm State 0xFFFF alarm,0x0000 no alarm 4. Read and modify the slave parametersIt supports reading and modifying the address and power alarm settings of the slave machine 5. Zero power 6. Calibration 7. CRC check Package List: 1 x Module1 x Data Cable1 x CT1 x User Manual Note: The module TTL interface is a passive interface, it needs external 5V power supply, all 4 ports must be linked at the time of communication, otherwise it can't communicate.
  • Identifiant Fruugo: 413522675-873947086
  • EAN: 7603816554106

Informations sur la sécurité des produits

Veuillez consulter les informations de sécurité du produit spécifiques à ce produit décrites ci-dessous.

Les informations suivantes sont fournies par le détaillant tiers indépendant vendant ce produit.

Étiquettes de sécurité des produits

CE Mark
Avertissements de sécurité: Warning: Please read the product instructions carefully before use to ensure correct use.
Numéro de série: 7603816554106

Livraison & retours

Expédition dans un délai de 2 jours

  • STANDARD: GRATUIT - Livraison entre mer. 15 octobre 2025–mer. 22 octobre 2025 - GRATUIT

Expédition de Chine.

Nous mettons tout en œuvre pour que les produits que vous commandez vous soient livrés dans leur intégralité et selon vos indications. Néanmoins, si vous recevez une commande incomplète, des articles différents de ceux commandés ou si, pour toute autre raison, la commande ne vous satisfait pas, vous pouvez retourner la commande ou tout produit inclus dans celle-ci et recevoir un remboursement complet des articles. Voir l'intégralité de la politique de retour

Détails de conformité du produit

Veuillez consulter les informations de conformité spécifiques à ce produit décrites ci-dessous.

Les informations suivantes sont fournies par le détaillant tiers indépendant vendant ce produit.

Fabricant:
Les informations suivantes indiquent les coordonnées du fabricant du produit concerné vendu sur Fruugo.

  • Wuhan Jinxingkai Network Technology Co., Ltd.
  • Wuhan Jinxingkai Network Technology Co., Ltd.
  • No. 1-1, Door 57
  • Shihua Village
  • Qingshan District
  • Wuhan
  • CN
  • 430000
  • goldxinks@163.com
  • 0086 17786498762
  • https://shop01473o1711614.1688.com/page/creditdetail.htm?spm=a261y.7663282.shopNavigation.1.6310755czE9SFQ

Personne responsable dans l'UE:
Les informations suivantes indiquent les coordonnées de la personne responsable dans l'UE. La personne responsable est l'opérateur économique désigné basé dans l'UE qui est responsable des obligations de conformité relatives au produit concerné vendu dans l'Union européenne.

  • None
  • Kequ Technology s.r.o.
  • Pražákova 1008/69
  • Štýřice
  • Jihomoravský kraj
  • Brno
  • CZ
  • 63900
  • christopher25106@outlook.com
  • 420608214795