Description
Features
1、Convert the 0-200Hz frequency pulse signal into an analog voltage signal of 0-5V. 2、Can be used to Convert interface between PLC and frequency, Or movement control card and converter interface matching control occasions. 3、Input pulse level is 5V 12V 24V can be directly input, no string resistor. However, the input signal frequency should be maintained for more than 0.5 seconds. 4、The output current is 5MA. 5、Frequency and voltage conversion module, response time is about 0.3-0.5 seconds.
Specification
Features:
2. Can be used to Convert interface between PLC and frequency, Or movement control card and converter interface matching control occasions.
3. Input pulse level is 5V 12V 24V can be directly input, no string resistor. However, the input signal frequency should be maintained for more than 0.5 seconds.
4. The output current is 5MA.
Specification:
Condition: 100% Brand New
Model: FV-200Hz5V
Function: Input 0-200Hz frequency is converted to 0-5V
Output Current: 5MA
Response Time: 0.3-0.5 seconds
Size: Approx. 4.5 x 4.7 x 1.7cm / 1.8 x 1.9 x 0.7in
Package List:
Precautions for use:
3. The signal input is isolated by diaphragm. Guaranteed anti-interference ability.
4. For use with PLC, support NPN type. Must have a ground wire.
5. If you need to use an encoder, the encoder should be rotated at a constant speed for more than 0.5 seconds.
7. If the signal input is turbine flow, etc., due to signal matching, an 817 diaphragm and a resistor must be added to match the flowmeter to normal function.
8. When using the correspondence, if there is a deviation, you can adjust the blue potentiometer on the board to adjust. At the time of shipment, we have adjusted the F/V potentiometer to a certain correspondence. It is generally not recommended to adjust it by itself.
Identification and wiring:
1. 12-30V--Power input positive
2. GND--Power input negative (common ground wire)
3. GND--Pulse frequency input negative (common ground wire)
4. 0-10KHZ--Pulse frequency input positive
5. GND--Pulse frequency input negative (common ground wire)
6. 0-10V-- Analog 0-10V level output
Correspondence & Linear Relationship:
20Hz is converted to 0.5V
100Hz is converted to 2.5V
200Hz is converted to 5V
Package List
-
Identifiant Fruugo:
271638852-602151326
-
EAN:
9308869116582
Informations sur la sécurité des produits
Veuillez consulter les informations de sécurité du produit spécifiques à ce produit décrites ci-dessous.
Les informations suivantes sont fournies par le détaillant tiers indépendant vendant ce produit.
Étiquettes de sécurité des produits
Avertissements de sécurité:
Please do not allow your child to handle this product alone to avoid swallowing or other injuries; adult supervision is recommended.
Livraison & retours
Expédition dans un délai de 2 jours
Expédition de Chine.
Nous mettons tout en œuvre pour que les produits que vous commandez vous soient livrés dans leur intégralité et selon vos indications. Néanmoins, si vous recevez une commande incomplète, des articles différents de ceux commandés ou si, pour toute autre raison, la commande ne vous satisfait pas, vous pouvez retourner la commande ou tout produit inclus dans celle-ci et recevoir un remboursement complet des articles. Voir l'intégralité de la politique de retour