Trigger Cycle Timer Delay Switch Single Channel Circuit Board Power MOS Tube Control Module Relay Module 7?24V

13,95 €
+ 10,49 € Livraison

Trigger Cycle Timer Delay Switch Single Channel Circuit Board Power MOS Tube Control Module Relay Module 7?24V

  • Marque: Unbranded

Trigger Cycle Timer Delay Switch Single Channel Circuit Board Power MOS Tube Control Module Relay Module 7?24V

  • Marque: Unbranded
Prix de vente conseillé : 26,95 €
Prix : 13,95 €
Vous économisez : 13,00 € (48%)
Verkocht door:
13,95 €
+ 10,49 € Livraison

En stock

Nous acceptons les modes de paiement suivants

Description

Item Type: Trigger Cycle Timer Delay Switch Product Model: YF-11 Application: Can control solenoid valves, water pumps, motors, light strips, etc. to run freely Input Voltage: DC 7~24V universal Output Power: DC load within 10A can be controlled Time Range: 0.01 second to 999 minutes, any time adjustable Wiring Port Description: 1. DC+: Input the positive pole of the DC power supply 2. DC-: Input the negative pole of the DC power supply 3. IN+: Positive signal input terminal 4. IN-: Negative signal input terminal 5. OUT+: Output positive 6. OUT-: Output negative Button Trigger: (Positive trigger: DC- and in- short circuited, DC+ and IN+ are connected to the button) Or: (Negative trigger: DC+ and in+ short circuited, DC- and IN- are connected to the button) Function List: P-11: Inching (start signal output, output stop when signal disappears) P-12: Self locking (start signal output once, stop signal output again) P-13: Give the signal, the output starts and stops automatically for A second; the trigger is invalid during the delay period P-14: Give the signal, the output will start and stop automatically for A second; trigger to re-timing during the delay period P-15: Give the signal, the output will start and stop automatically for A second; during the delay period, the superposition timer will be triggered P-16: Gives the signal, the output starts and stops automatically for A second; reset is triggered during the delay period P-17: Give the signal, the output starts, the input signal is disconnected, the power is turned off after the start of timing A second, and the signal is kept output during the delay period, and the timing stops P-18: After power on, the output will start, and the power will be turned off after a delay of A seconds; until the next power on P-21: Give the signal, after a delay of A seconds, the output will start P-22: Give the signal, after more than A second, the output starts, the signal disappears, and the output stops P-23: After the signal disappears for more than A seconds, the output starts, there is a signal, and the output stops P-24: There is a signal, the output will start after A second, and the output will stop after the signal disappears for more than A second P-25: When there is a signal, the output will start after more than A second, and the output will stop after more than A second when there is a signal P-26: When there is a signal, the output will stop after A second after the start, and the output will stop after A second after the signal disappears. P-27: Detection of a pulse signal, the output stops; no pulse signal, more than A second output start; (the signal continues or the signal disappears are regarded as no pulse signal) P-28: After power on, after a delay of A second, the output starts until the power is off P-31: After power on, the output starts for A second, stops for B second, infinite loop; power off stops P-32: When there is a signal, start P-31 infinite loop; when the signal disappears, terminate the loop P-33: Give a signal to start P-31 infinite loop; give another signal to terminate the loop P-34: After power on, after a delay of A second, the output will start, and it will stop after closing B seconds P-35: There is a signal, after a delay of A second, the output will start, and it will stop after the pull in for B seconds P-36: There is a signal, the output will start after A second, and stop after B second, the signal disappears, and the timer will be cleared and stopped. P-37: When there is a signal, the output starts and stops automatically for A seconds, and then counts for B seconds after it stops. The signal trigger is invalid within the time A+B. P-38: There is a signal, the output starts and stops automatically for A second, after stopping and counting for B seconds, restarting for A second automatically stops P-41: No action with signal; trigger when signal disappears; disconnect after output start delay A time P-42: The signal disappears, after a delay of time A, the output starts; working time B ends P-43: The signal disappears, after the time A exceeds, the output starts; the working time B ends P-44: After power on, the output will start A time, stop B time; cycle C times and automatically stop. P-45: No action when energized, after signal is given; output starts A time, stops B time; cycles C times and automatically stops; Give signal again, execute again P-46: After giving the signal more than A times, the output will start; keep the output; stop when the power is off P-47: After giving the signal more than A times, the output starts and stops for B seconds P-48: Within C seconds, after continuously giving the signal more than A times, the output starts and stops in B seconds Button Setting Instructions: power on display "----" means entering the standby state; Press K
  • Identifiant Fruugo: 325685022-721032431
  • EAN: 7295624183434

Informations sur la sécurité des produits

Veuillez consulter les informations de sécurité du produit spécifiques à ce produit décrites ci-dessous.

Les informations suivantes sont fournies par le détaillant tiers indépendant vendant ce produit.

Avertissements de sécurité: Do not let your children touch this product alone to avoid swallowing or other injuries.

Livraison & retours

Expédition dans un délai de 3 jours

  • STANDARD: 10,49 € - Livraison entre jeu. 02 octobre 2025–jeu. 09 octobre 2025

Expédition de Chine.

Nous mettons tout en œuvre pour que les produits que vous commandez vous soient livrés dans leur intégralité et selon vos indications. Néanmoins, si vous recevez une commande incomplète, des articles différents de ceux commandés ou si, pour toute autre raison, la commande ne vous satisfait pas, vous pouvez retourner la commande ou tout produit inclus dans celle-ci et recevoir un remboursement complet des articles. Voir l'intégralité de la politique de retour

Détails de conformité du produit

Veuillez consulter les informations de conformité spécifiques à ce produit décrites ci-dessous.

Les informations suivantes sont fournies par le détaillant tiers indépendant vendant ce produit.

Fabricant:
Les informations suivantes indiquent les coordonnées du fabricant du produit concerné vendu sur Fruugo.

  • 91440300MA5HDL2A4K
  • SHEN ZHEN SHI LAI LI ZHU BAO SHI PIN MAO YI YOU XIAN GONG SI
  • Room B, 21F, Block A, Jingang Huating, 4009 Baoan Avenue, Yantian Community, Xixiang Street, Baoan District, Shenzhen
  • Shenzhen
  • CN
  • 518102
  • 939301410@qq.com
  • 15625700418

Personne responsable dans l'UE:
Les informations suivantes indiquent les coordonnées de la personne responsable dans l'UE. La personne responsable est l'opérateur économique désigné basé dans l'UE qui est responsable des obligations de conformité relatives au produit concerné vendu dans l'Union européenne.

  • 950891051
  • MJCM SARL
  • 78 avenue des Champs Elysees Bureau 326, 75008 Paris, France
  • Paris
  • FR
  • 75008
  • mjcm190928@gmail.com
  • 0033 767213611