DC Current Detection Module, 10A Relay Output, YYI-2 Model, Digital Display Motor Controller 12V

21,95 €
+ 8,49 € Livraison

DC Current Detection Module, 10A Relay Output, YYI-2 Model, Digital Display Motor Controller 12V

  • Marque: Unbranded
Verkocht door:

DC Current Detection Module, 10A Relay Output, YYI-2 Model, Digital Display Motor Controller 12V

  • Marque: Unbranded

21,95 €

Économisez 12,00 € (35%)

Prix de vente recommandé

33,95 €
En stock
+ 8,49 € Livraison

Politique de retour sur 14 jours

Verkocht door:

21,95 €

Économisez 12,00 € (35%)

Prix de vente recommandé

33,95 €
En stock
+ 8,49 € Livraison

Politique de retour sur 14 jours

Modes de paiement:

Description

DC Current Detection Module, 10A Relay Output, YYI-2 Model, Digital Display Motor Controller 12V

①. DC Current Detection Module Relay Switch Sensor Digital Display Motor Controller 12V ②. Item Type: DC Current Detection Module ③. Product Model: YYI-2. When the detection current is too large or too small, the control relay switch will control the circuit to be on or off, or give a signal; ④. Detection Accuracy: 0.01A (10mA) ⑤. Error Calibration: With error calibration function, and the display can be turned off for a long time to reduce power consumption; ⑥. Standby Current: About 20mA; ⑦. Relay Output: Can control the on and off of DC lines within 10A; ⑧. Function ⑨. 1. P-11: When the measured current is greater than I1, the relay is closed; when the measured current is less than I1 again, the relay is disconnected; ⑩. 2. P-12: When the measured current is greater than I1, the relay is closed; and it will always stay closed until the circuit board is powered off; ⑪. 3. P-21: When the measured current is greater than I2, the relay is closed; when the measured current is less than I1, the relay is disconnected; ⑫. 4. P-22: When the measured current is greater than I2, the relay is closed; and it will always stay closed until the circuit board is powered off; ⑬. 5. P-31: When the measured current is less than I1, the relay is closed; when the current is greater than I2, the relay is disconnected; ⑭. 6. P-32: When the measured current is less than I1, the relay is closed; and it will always stay closed until the circuit board is powered off; ⑮. 7. P-41: When the measured current is between I1 and I2, the relay is closed, otherwise the relay is disconnected; ⑯. 8. P-42: When the measured current is between I1 and I2, the relay is closed; and it will always stay closed until the circuit board is powered off; ⑰. 9. P-51: When the measured current is less than I1 or greater than I2, the relay is closed, otherwise the relay is disconnected; ⑱. 10. P-52: When the measured current is less than I1 or greater than I2, the relay is closed; and it will always stay closed until the circuit board is powered off; ⑲. Setting Instructions: ⑳. 1. Power on to display the measured current; (if the measured current terminal is suspended, the number of digital display is normal); ㉑. 2. The first time K1 is pressed, it takes more than 1 second to be effective to prevent false triggering. The screen displays: P 11: K2 adjustment mode, K3 adjustment function; ㉒. 3. Press K1 for the second time, the screen flashes: 0.05 means that the value of the threshold I1 is 0.05A; K2 sets I1 plus, K3 sets I1 minus; ㉓. 4. Press K1 for the third time, the screen flashes: 0.10 means the value of the threshold I2 is 0.1A; K2 sets I2 plus, K3 sets I2 minus; ㉔. 5. Press K1 for the fourth time, the screen displays the measured current; it means it enters the standby state; ㉕. 6. In standby mode, long press K2 or K3 to fine tune the measured current error.
  • Identifiant Fruugo: 462328378-973119946

Livraison & retours

Expédition dans un délai de 3 jours

  • STANDARD: 8,49 € - Livraison entre mar. 10 février 2026–jeu. 19 février 2026

Expédition de Chine.

Nous mettons tout en œuvre pour que les produits que vous commandez vous soient livrés dans leur intégralité et selon vos indications. Néanmoins, si vous recevez une commande incomplète, des articles différents de ceux commandés ou si, pour toute autre raison, la commande ne vous satisfait pas, vous pouvez retourner la commande ou tout produit inclus dans celle-ci et recevoir un remboursement complet des articles. Voir l'intégralité de la politique de retour

Détails de conformité du produit

Veuillez consulter les informations de conformité spécifiques à ce produit décrites ci-dessous.

Les informations suivantes sont fournies par le détaillant tiers indépendant vendant ce produit.

Fabricant:
Les informations suivantes indiquent les coordonnées du fabricant du produit concerné vendu sur Fruugo.

  • Guangzhou Qiyi E-Commerce Co., Ltd.
  • LnitOne2
  • 3 Tangdong East Road, Unit 216, G282
  • Tianhe District
  • Guangzhou
  • china
  • 510620
  • qiyihappiness@163.com
  • (+86) 16620020838

Personne responsable dans l'UE:
Les informations suivantes indiquent les coordonnées de la personne responsable dans l'UE. La personne responsable est l'opérateur économique désigné basé dans l'UE qui est responsable des obligations de conformité relatives au produit concerné vendu dans l'Union européenne.

  • Jessie Peng
  • Axitera GmbH
  • Kreuznacher Str. 30, D-60486 Frankfurt am Main, Hessen,
  • Frankfurt am Main
  • Germany
  • 60486
  • successservice3@gmail.com
  • (+49) 6934873848