Description
Features
1. Input point X element x0-x7, DC24 input, low level valid. X0-5 is the high-speed counting input port (default: 12K,100KHZ optional).
2. Output analog voltage WR3A instruction, corresponding to the value 0-4095.
3. The maximum speed current is 1A. External load common terminating + 24, the other end received the PLC output port Y.
4. Y0-Y5 is optional relay or transistor output, relay output current 5A. The transistor output DC24V, the current maximum 1A.
5. Intermediate relay M: M0-M3071, the power loss preservation range can be set.
Features:
Input point X element x0-x7, DC24 input, low level valid. X0-5 is the high-speed counting input port (default: 12K,100KHZ optional).
Output analog voltage WR3A instruction, corresponding to the value 0-4095.
The maximum speed current is 1A. External load common terminating + 24, the other end received the PLC output port Y.
Y0-Y5 is optional relay or transistor output, relay output current 5A. The transistor output DC24V, the current maximum 1A.
Intermediate relay M: M0-M3071, the power loss preservation range can be set.
Specification:
Weight: 239g/8.4oz
Input point:8
Output point:6
Power supply voltage: DC24V
Output current: 5A
Analog input: 6AD
Analog output: 2DA
High speed count:6 road 12K optional 100K
Pulse output: No
Floating point: Support
Step motor: No support
Memory capacity:8000 step
Programming software: GX developer or GX works
Program steps: 8000 steps
Two communication ports:
One RS232 (DB9) serial communication port is FX3u protocol 38400,7, E, 1;
One RS485 (485 optional configuration) (communication protocol can be set to D8120).
The output point Y element:
Y0-Y5 is optional relay or transistor output, relay output current 5A. The transistor output DC24V, the current maximum 1A.
Y0-1 is high-speed output port (maximum 100K). PWM period is 0-32767US. High
The maximum speed current is 1A. External load common terminating + 24, the other end received the PLC output port Y.
Analog input:
Six-way analog input,12 bit accuracy, input voltage:0-10V,0-20MA; Read the analog quantity with RD3A directive. The corresponding values 0-4095. Two-way potentiometer analog input, D8030, D8031.
Analog output:
2-channel analog output, 12-bit accuracy, output voltage: 0-10v. Output analog voltage WR3A instruction, corresponding to the value 0-4095.
Intermediate relay M: M0-M3071, the power loss preservation
Package List
-
Identifiant Fruugo:
397203922-847492333
-
EAN:
9789622287693
Informations sur la sécurité des produits
Veuillez consulter les informations de sécurité du produit spécifiques à ce produit décrites ci-dessous.
Les informations suivantes sont fournies par le détaillant tiers indépendant vendant ce produit.
Étiquettes de sécurité des produits
Avertissements de sécurité:
Please do not allow your child to handle this product alone to avoid swallowing or other injuries; adult supervision is recommended.
Ingrédients:
As shown in the figure
Livraison & retours
Expédition dans un délai de 2 jours
Expédition de Chine.
Nous mettons tout en œuvre pour que les produits que vous commandez vous soient livrés dans leur intégralité et selon vos indications. Néanmoins, si vous recevez une commande incomplète, des articles différents de ceux commandés ou si, pour toute autre raison, la commande ne vous satisfait pas, vous pouvez retourner la commande ou tout produit inclus dans celle-ci et recevoir un remboursement complet des articles. Voir l'intégralité de la politique de retour